<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-11 15-01-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 50 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 74 kHz 14036 27,6218
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 6,13 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 74 kHz MIN: 11 kHz % above 76 kHz: 27,6218 Acquired: 2026.09.11 15.00.03 Total samples: 14036 Equivalent time: 0:11:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 7,1 dBr MIN: 4,3 dBr AVE: 6,13 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026.09.11 15.00.02) 14.46 14.48 14.50 14.52 14.54 14.56 14.58 15.00 0 2 4 6 8 Pm [dBr]